Incompatibilities: Varilrix should not be mixed with other vaccines in the same syringe.
Instructions for Use/Handling:
Due to minor variations of its pH, the colour of the reconstituted vaccine may vary from clear peach to pink coloured solution.
The solvent and the reconstituted vaccine should be inspected visually for any foreign particulate matter and/or variation of physical aspect prior to reconstitution or administration. In the event of either being observed, do not use the solvent or the reconstituted vaccine.
Instructions for reconstitution of the vaccine with solvent presented in ampoules: Varilrix must be reconstituted by adding the entire contents of the supplied ampoule of solvent to the vial containing the powder. The mixture should be well shaken until the powder is completely dissolved in the solvent.
After reconstitution, the vaccine should be used promptly.
Withdraw the entire contents of the vial.
A new needle should be used to administer the vaccine.
Instructions for reconstitution of the vaccine with solvent presented in pre-filled syringe: Varilrix must be reconstituted by adding the entire contents of the pre-filled syringe of solvent to the vial containing the powder.
To attach the needle to the syringe, carefully read the instructions given. However, the syringe provided with Varilrix might be slightly different than the syringe described.
Always hold the syringe by the barrel, not by the syringe plunger or the Luer Lock Adaptor (LLA), and maintain the needle in the axis of the syringe. Failure to do this may cause the LLA to become distorted and leak.
During assembly of the syringe, if the LLA comes off, a new vaccine dose (new syringe and vial) should be used.
1) Unscrew the syringe cap by twisting it anticlockwise.
2) Attach the needle to the syringe by gently connecting the needle hub into the LLA and rotate a quarter turn clockwise until it locks.
3) Remove the needle protector, which may be stiff.
4) Add the solvent to the powder. The mixture should be well shaken until the powder is completely dissolved in the solvent.
After reconstitution, the vaccine should be used promptly.
5) Withdraw the entire contents of the vial.
6) A new needle should be used to administer the vaccine. Unscrew the needle from the syringe and attach the injection needle by repeating step 2 mentioned previously.
Any unused product or waste material should be disposed of in accordance with local requirements.