Vabysmo

Vabysmo Caution For Usage

faricimab

Manufacturer:

Roche

Distributor:

DKSH
Full Prescribing Info
Caution For Usage
Special precautions for disposal: Do not shake.
The vial contains more than the recommended dose of 6 mg. The fill volume of the vial (0.24 mL) is not to be used in total. The excess volume should be expelled prior to injection. Injecting the entire volume of the vial results in overdose. The injection dose must be set to the 0.05 mL dose mark, i.e. 6 mg faricimab.
Vabysmo should be inspected visually upon removal from the refrigerator and prior to administration. If particulates or cloudiness are visible, the vial must not be used. The contents of the vial and the transfer filter needle are sterile and for single use only. Do not use if the packaging, vial and/or transfer filter needle are damaged or expired. Detailed instructions for use are provided in Instructions for use of vial as follows.
Any unused medicinal product or waste material should be disposed of in accordance with local requirements.
Instructions for use of vial: 1. Gather the following supplies: One Vabysmo vial (included); One sterile 5-micron blunt transfer filter needle 18-gauge x 1½ inch, 1.2 mm x 40 mm (included); One sterile 1 mL Luer lock syringe with a 0.05 mL dose mark (not included); One sterile injection needle 30-gauge x ½ inch (not included); Alcohol swab (not included). Note that a 30-gauge injection needle is recommended to avoid increased injection forces that could be experienced with smaller diameter needles.
2. To ensure all liquid settles at the bottom of the vial, place the vial upright on a flat surface (for about 1 minute) after removal from packaging. Gently tap the vial with the finger, as liquid may stick to the top of the vial.
3. Remove the flip-off cap from the vial and wipe the vial septum with an alcohol swab.
4. Aseptically and firmly attach the included 18-gauge x 1½ inch transfer filter needle onto a 1 mL Luer lock syringe.
5. Using aseptic technique, push the transfer filter needle into the center of the vial septum, push it all the way in, then tilt the vial slightly so that the needle touches the bottom edge of the vial.
6. Hold the vial slightly inclined and slowly withdraw all the liquid from the vial. Keep the bevel of the transfer filter needle submerged in the liquid, to avoid introduction of air.
7. Ensure that the plunger rod is drawn sufficiently back when emptying the vial, in order to completely empty the transfer filter needle.
8. Disconnect the transfer filter needle from the syringe and dispose of it in accordance with local regulations. Do not use the transfer filter needle for the intravitreal injection.
9. Aseptically and firmly attach a 30-gauge x ½ inch injection needle onto the Luer lock syringe.
10. Carefully remove the plastic needle shield from the needle by pulling it straight off.
11. To check for air bubbles, hold the syringe with the needle pointing up. If there are any air bubbles, gently tap the syringe with the finger until the bubbles rise to the top.
12. Carefully expel the air from the syringe and needle, and slowly depress the plunger to align the rubber stopper tip to the 0.05 mL dose mark. The syringe is ready for the injection. Ensure that the injection is given immediately after preparation of the dose.
13. Inject slowly until the rubber stopper reaches the end of the syringe to deliver the volume of 0.05 mL. Confirm delivery of the full dose by checking that the rubber stopper has reached the end of the syringe barrel. Any waste material or unused medicinal product should be disposed of in accordance with local regulations.
Incompatibilities: In the absence of compatibility studies, this medicinal product must not be mixed with other medicinal products.